Home » IRC Modular Homes
HUD | MODULAR |
---|---|
1. Frame remains on home | 1. Removeable frame which is returned to plant |
2. 2″x6″ or 2″x8″ Floor Joists 16″ OC | 2. 2″x10″ Floor Joists 16″ OC |
3. Single 2″x6″ (or 2″x8″) Rim Rail Around Floor | 3. Double 2″x10″ Rim Rails Around floor |
4. Exterior walls have 2″x6″ Top Plates and 1″x6″ Bottom Plates | 4. Exterior walls have Double 2″x6″ Top Plate and 2″x6″ Bottom plate |
5. Cedar Canyon, Cedar Canyon LS & Pinehurst Interior walls with 2″x4″ studs 24″ OC with 2″x4″ Top Plate and 1″x4″ Bottom Plate | 5. Cedar Canyon, Cedar Canyon LS & Pinehurst Interior walls with 2″x4″ studs 24″ OC with 2″x4″ Top & Bottom Plates |
6. Grand Manor Interior walls with 2″x4″ studs 16″ OC with 2″x4″ Top Plate and 1″x4″ Bottom Plate | 6. Grand Manor Interior walls with 2″x4″ studs 16″ OC with 2″x4″ Top and Bottom Plates |
7. 30# Roof Load (HUD Rafter) | 7. 30# Roof Load (IRC Modular Rafter) |
8. Roof Pitches: 2.66:12 on 40 Wides, 4:12 on 28 Wides with 14″ eaves, 3.31:12 on 30 Wides & 44 Wides with 12″ eaves | 8. Roof Pitches on all houses at 3:12 with 12″ eaves |
9. Insulation R-40 Roof, R-21 Wall, R-33 Floor | 9. Insulation R-50 Roof, R-21 Wall and R-30 Floor (some jurisdictions require R-5 Foam insulation on exterior walls |
10. 5/8″ Tongue & Groove OSB Floor Decking | 10. 3/4″ Tongue & Groove OSB Floor Decking |
11. Typical Window & Door Headers are single 2″x6″ Lay Flat Headers (depend on size of window and roof load) | 11. Double Vertical 2″x4″ Window & Door Headers (depend on size of window opening and roof load) |
12. 7/16″ OSB Underlayment w/House Wrap installed under Lap and vinyl siding only–Not installed under Smart Panel | 12. 7/16″ OSB Underlayment w/House Wrap installed under all exterior sidings |
13. 3/8″ Facia Board | 13. 5/4 Facia Board |
14. 40 Gallon Electric Water Heater (50 gallon in Grand Manor) | 14. 50 Gallon Electric Water Heater |
15. Plumbing with auto vents and some vents through roof | 15. All plumbing vents through roof |
16. No Water Softener Plumbing Loop required | 16. Water Softener plumbing loop (only required in certain jurisdictions) |
17. Drain water system complete | 17. Drain system plumbed through floor with on site work required |
18. 1-1/2″ Drain and P-traps | 18. 2″ Drain and P-traps on tubs & showers |
19. 1″x6″ Sub Facia | 19. 2″x4″ Sub Facia |
20. Whole House Water Shutoff Valve included in laundry plumbing hook up box | 20. Separate Whole House Water Shutoff valve box |
21. Cedar Canyon, Cedar Canyon LS and Pinehurst with non-FHA grade carpet, Grand Manor with FHA grade carpet | 21. FHA Grade Carpet |
22. Smoke detectors in all bedrooms and in living areas | 22. Smoke detectors inside each bedroom and outside each bedroom area and in living areas |
23. High Efficacy Lighting Not Required | 23. 75% High Efficacy Lighting |
1000 Garber Street
Caldwell, ID 83606
(208) 454-5000
Powered by ManufacturedHomes.com